Изображение может быть репрезентативным.
Подробную информацию о продукте см. в характеристиках.
P51-200-A-A-M12-20MA-000-000

P51-200-A-A-M12-20MA-000-000

Product Overview

Category

The P51-200-A-A-M12-20MA-000-000 belongs to the category of industrial pressure transducers.

Use

It is used for measuring and transmitting pressure readings in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The P51-200-A-A-M12-20MA-000-000 is typically packaged in a protective casing to ensure durability during transportation and installation.

Essence

The essence of this product lies in its ability to provide precise and reliable pressure measurements in demanding industrial environments.

Packaging/Quantity

The product is usually available as a single unit in its packaging.

Specifications

  • Pressure Range: 0-200 psi
  • Output: 4-20 mA
  • Electrical Connection: M12 Connector
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel

Detailed Pin Configuration

The detailed pin configuration of the P51-200-A-A-M12-20MA-000-000 is as follows: 1. V+ 2. Signal + 3. Signal - 4. V-

Functional Features

  • High precision measurement
  • Compatibility with various liquids and gases
  • Easy integration into existing systems
  • Low power consumption
  • Built-in overpressure protection

Advantages

  • Accurate and reliable pressure readings
  • Suitable for harsh industrial environments
  • Long-term stability
  • Easy installation and integration

Disadvantages

  • Limited pressure range compared to some other models
  • May require additional accessories for certain installations

Working Principles

The P51-200-A-A-M12-20MA-000-000 operates on the principle of strain gauge technology, where the applied pressure causes deformation in the sensing element, resulting in a change in electrical resistance. This change is then converted into a proportional electrical signal.

Detailed Application Field Plans

This pressure transducer is widely used in industries such as: - Oil and gas - Chemical processing - Automotive manufacturing - Aerospace - HVAC systems

Detailed and Complete Alternative Models

Some alternative models to consider are: - P51-100-A-A-I36-20MA-000-000 - P51-500-A-A-M12-20MA-000-000 - P51-200-B-A-M12-20MA-000-000

In conclusion, the P51-200-A-A-M12-20MA-000-000 is a highly reliable and accurate industrial pressure transducer suitable for a wide range of applications, despite its limited pressure range compared to some alternatives.

[Word Count: 345]

Перечислите 10 распространенных вопросов и ответов, связанных с применением P51-200-A-A-M12-20MA-000-000 в технических решениях.

  1. What is the P51-200-A-A-M12-20MA-000-000 sensor used for?

    • The P51-200-A-A-M12-20MA-000-000 sensor is commonly used for measuring pressure in various technical applications.
  2. What is the operating range of the P51-200-A-A-M12-20MA-000-000 sensor?

    • The operating range of the P51-200-A-A-M12-20MA-000-000 sensor is typically from 0 to 200 psi.
  3. What type of output signal does the P51-200-A-A-M12-20MA-000-000 sensor provide?

    • The P51-200-A-A-M12-20MA-000-000 sensor provides a 4-20mA output signal, which is commonly used in industrial applications.
  4. Is the P51-200-A-A-M12-20MA-000-000 sensor suitable for use in harsh environments?

    • Yes, the P51-200-A-A-M12-20MA-000-000 sensor is designed to withstand harsh environmental conditions and is often used in rugged industrial settings.
  5. What are the typical applications for the P51-200-A-A-M12-20MA-000-000 sensor?

    • The P51-200-A-A-M12-20MA-000-000 sensor is commonly used in hydraulic systems, pneumatic systems, industrial machinery, and process control applications.
  6. Does the P51-200-A-A-M12-20MA-000-000 sensor require calibration?

    • Yes, like most sensors, the P51-200-A-A-M12-20MA-000-000 sensor may require periodic calibration to ensure accurate and reliable measurements.
  7. Can the P51-200-A-A-M12-20MA-000-000 sensor be integrated with PLCs or control systems?

    • Yes, the P51-200-A-A-M12-20MA-000-000 sensor can be easily integrated with programmable logic controllers (PLCs) and other control systems using its 4-20mA output signal.
  8. What is the temperature range within which the P51-200-A-A-M12-20MA-000-000 sensor operates?

    • The P51-200-A-A-M12-20MA-000-000 sensor typically operates within a temperature range of -40°C to 85°C.
  9. Is the P51-200-A-A-M12-20MA-000-000 sensor compatible with corrosive media?

    • Yes, the P51-200-A-A-M12-20MA-000-000 sensor is often constructed with materials that make it compatible with corrosive media, making it suitable for a wide range of applications.
  10. What is the response time of the P51-200-A-A-M12-20MA-000-000 sensor?

    • The response time of the P51-200-A-A-M12-20MA-000-000 sensor is typically fast, allowing for real-time monitoring and control in dynamic systems.