Изображение может быть репрезентативным.
Подробную информацию о продукте см. в характеристиках.
BTA2008-1000D,126

BTA2008-1000D,126

Product Category

The BTA2008-1000D,126 belongs to the category of power semiconductor devices.

Basic Information Overview

  • Use: The BTA2008-1000D,126 is used for controlling high power inductive or resistive loads in a variety of applications.
  • Characteristics: It features high current capability, low holding current for improved noise immunity, and high commutation capability.
  • Package: The device is available in a TO-220AB package.
  • Essence: Its essence lies in providing reliable and efficient control of high-power loads.
  • Packaging/Quantity: Typically packaged in reels, the quantity varies based on customer requirements.

Specifications

  • Voltage Rating: 1000V
  • Current Rating: 20A
  • Gate Trigger Current: 50mA
  • On-State Voltage: 1.55V
  • Holding Current: 30mA
  • Critical Rate of Rise of Off-State Voltage: 50V/µs

Detailed Pin Configuration

The BTA2008-1000D,126 has a standard TO-220AB pin configuration with three pins: gate (G), main terminal 1 (MT1), and main terminal 2 (MT2).

Functional Features

  • High Current Capability: Capable of handling high currents, making it suitable for demanding applications.
  • Low Holding Current: Improved noise immunity due to low holding current.
  • High Commutation Capability: Efficiently commutates high inductive loads.

Advantages and Disadvantages

  • Advantages:
    • High current capability allows for versatile use.
    • Low holding current improves noise immunity.
    • High commutation capability ensures efficient load control.
  • Disadvantages:
    • Sensitive to voltage spikes and transients.
    • Requires careful thermal management at high currents.

Working Principles

The BTA2008-1000D,126 operates based on the principles of thyristor technology, utilizing a gate signal to control the conduction of high-power loads.

Detailed Application Field Plans

The BTA2008-1000D,126 finds extensive application in: - Industrial motor control systems - Heating and lighting control - Power supplies and UPS - Solid-state relays

Detailed and Complete Alternative Models

  • BTA208X-1000D,126: Similar specifications with enhanced transient protection.
  • BTA2008-1200D,126: Higher voltage rating for specific applications.

This comprehensive entry provides an in-depth understanding of the BTA2008-1000D,126, its specifications, features, and applications, catering to the needs of professionals and enthusiasts in the field of power electronics.

Перечислите 10 распространенных вопросов и ответов, связанных с применением BTA2008-1000D,126 в технических решениях.

  1. What is the BTA2008-1000D,126 used for in technical solutions?

    • The BTA2008-1000D,126 is a high voltage Triac designed for use in AC switching and control applications.
  2. What is the maximum voltage and current rating of the BTA2008-1000D,126?

    • The BTA2008-1000D,126 has a maximum voltage rating of 1000V and a maximum current rating of 8A.
  3. What are the typical applications for the BTA2008-1000D,126?

    • Typical applications include dimmers, motor control, heating control, and general AC switching.
  4. What is the recommended operating temperature range for the BTA2008-1000D,126?

    • The recommended operating temperature range is -40°C to 125°C.
  5. Does the BTA2008-1000D,126 require a heat sink for operation?

    • Yes, it is recommended to use a heat sink for efficient thermal management, especially when operating at higher currents.
  6. What is the gate trigger current for the BTA2008-1000D,126?

    • The gate trigger current typically ranges from 5mA to 50mA.
  7. Can the BTA2008-1000D,126 be used for both AC and DC applications?

    • No, the BTA2008-1000D,126 is specifically designed for AC applications.
  8. What is the isolation voltage for the BTA2008-1000D,126?

    • The isolation voltage is typically around 2500Vrms.
  9. Is the BTA2008-1000D,126 RoHS compliant?

    • Yes, the BTA2008-1000D,126 is RoHS compliant.
  10. Are there any specific precautions to consider when using the BTA2008-1000D,126 in technical solutions?

    • It is important to follow proper handling and assembly procedures to avoid damage to the device, and to ensure proper electrical insulation and heat dissipation.